欢迎来到360期刊网!
学术期刊
  • 学术期刊
  • 文献
  • 百科
电话
您当前的位置:

首页 > 文献资料

  • 作者:

    Objective:The present study was designed to test the hypothesis that inflammation is involved in the end-organ damage(EOD) induced by sinoaortic denervation(SAD) in rats.Method:SAD was performed in male Sprague-Dawley rats at the age of 10 weeks.Under anaesthesia,aortic nerves were cut and the sinus region of the carotid artery was stripped and painted with 10% phenol.Pathological evaluation of EOD and the determination of plasma or tissue levels of the factors related to inflammation,including thromboxane B2(TXB2) interleukin-1(IL-1),tumour necrosis factor α(TNF-α) and reactive oxygen species(ROS) were performed at 16 weeks after SAD.Pathological evaluation of EOD included heart weigh ratio,myocardial and blood vessel hydroxyproline and collagen volume fraction,glomerular injury score and number of infiltrating inflammatory cells.Indomethacin(20 mg/kg per day,orally) or vitamin E(100 mg/kg per day,orally) was administered for 12 weeks,beginning from4 weeks after SAD,to observe their effects on SAD-induced EOD.Results:There were significant fibrosis and inflammatory infiltration in the myocardium and blood vessels,represented by higher hydroxyproline and collagen volume fraction,and a large amount of inflammatory cells in the tissues of SAD rats.Heart weight and kidney glomerular injury score were significantly higher in ed significantly after SAD.Indomethacin and vitamin E significantly decreased the contents of some factors related to inflammation in SAD rats.Both drugs also alleviated myocardial and vessel fibrosis,inflammatory infiltration and kidney damage.Conclusion:Inflammation is involved in the organ damage induced by SAD in rats.

  • 作者:

    Cone-beam computed tomography (CBCT) has been recently used to analyse trabecular bone structure around dental implants. To validate the use of CBCT for three-dimensional (3D) peri-implant trabecular bone morphometry by comparing it to two-dimensional (2D) histology, 36 alveolar bone samples (with implants n527 vs. without implants n59) from six mongrel dogs, were scanned ex vivo using a high-resolution (80 mm) CBCT. After scanning, all samples were decalcified and then sectioned into thin histological sections (,6 mm) to obtain high contrast 2D images. By using CTAn imaging software, bone morphometric parameters including trabecular number (Tb.N), thickness (Tb.Th), separation (Tb.Sp) and bone volume fraction (BV/TV) were examined on both CBCT and corresponding histological images. Higher Tb.Th and Tb.Sp, lower BV/TV and Tb.N were found on CBCT images (P,0.001). Both measurements on the peri-implant trabecular bone structure showed moderate to high correlation (r50.65-0.85). The Bland-Altman plots showed strongest agreement for Tb.Th followed by Tb.Sp, Tb.N and BV/TV, regardless of the presence of implants. The current findings support the assumption that peri-implant trabecular bone structures based on high-resolution CBCT measurements are representative for the underlying histological bone characteristics, indicating a potential clinical diagnostic use of CBCT-based peri-implant bone morphometric characterisation.

360期刊网

专注医学期刊服务15年

  • 您好:请问您咨询什么等级的期刊?专注医学类期刊发表15年口碑企业,为您提供以下服务:

  • 1.医学核心期刊发表-全流程服务
    2.医学SCI期刊-全流程服务
    3.论文投稿服务-快速报价
    4.期刊推荐直至录用,不成功不收费

  • 客服正在输入...

x
立即咨询